Forced system sewage pumps residential system

The need for installation of forced sanitation ( sewage pumps ) often arises not only in the construction of individual houses , but also during the renovation and conversion of conventional apartments. Sewage pumps allow to implement any engineering and design decisions and allow you to place the kitchen, bathroom or toilet without a hard peg to the sewer standpipe . Sometimes it is impossible to make a house or apartment as comfortable as possible without moving the kitchen or bathroom a place remote from the riser . Question can be solved in the traditional way , extending the pipe. But this process is time consuming , expensive and quite uncomfortable.

 

The simplest solution  installation of forced drainage

What are sewage pumps ?

This compact pump stations, which are pre- accumulate , process , and then pumped waste water to a common sewer system to the treatment plant or septic tank. The big advantage of such systems is their ability to pump waste water not only horizontally ( from 10 to 100 meters), but also vertically ( from 3 to 7 meters) . System ( UPKS ) requires power from 220 V – 50 Hz. UPKS sold ready for use , the only condition – is the installation of electrical grounding outlet in a convenient location and protection installation with RCD.

 

Review Of Macerator And Sewage Pumps Gc And Gd

This setup is similar to a simple toilet tank . Typically , the housing is made of impact-resistant plastic white. Compact dimensions, can easily hide UPKS for sanitary equipment to which it is attached , so that the overall look of the room is not disturbed.

 

Standard Classification UPKS does not exist, but all the equipment is divided into groups on several grounds :

Presence or absence of the chopper .
The duration of installation.
Temperature of pumped wastewater ( up to 90 degrees hot , cold to 40) .
Performance .
Thus, all the settings are divided into groups based on two characteristics : no chopper and the chopper for cold and hot wastewater. Let us consider all the groups :

Systems for hot forced sewer drains without comminution

Installation scavenge “clean” waste water heat bath, sink , dishwasher and washing machine. This type UPKS ideal when a bathroom , kitchen or laundry room moved a great distance from the main riser to the basement or ground floor . This compact unit that can be installed in any convenient place to hang on the wall , place to hide in a closet or under a sink . Pumping wastewater in UPKS this type is due to the powerful pumps . Installing drains withstand temperatures up to 90 degrees . This type of design in our market is represented by several manufacturing companies . The cost ranges from 300 to 800 euros.

 

Zoeller Grinder Sewage Pump – Awesome Power! Review

Systems forced sanitation ( sewage pumps ) with chopper hot effluent

It is a universal system with high performance, capable of withstanding temperatures of wastewater to 95 degrees and grind thick waste. Availability shredder lets you connect to UPKS sink, shower , bidet, washing machine and dishwasher , as well  . With powerful knives , which is equipped with a chopper , the installation can easily grind personal hygiene items and small items , accidentally fell into the toilet. Even if UPKS hit a hard object – it is not able to bring it down , the subject will simply lie on the bottom of the housing. Cost UPKS this type ranges from 450 to 950 euros  from the manufacturer .

Systems – compulsory sanitation ( sewage pumps ) with chopper cold drains
UPKS have this kind usually behind the toilet . This installation represents a compact container which is located inside the pump and shredder faecalis . Flowing grinds everything in it misses , and then processed by a pump waste is transported to the branch pipe to the destination. Job shredder eliminates the branch pipes of large diameter. Included with this type sold UPKS flexible rubber coupling for connecting the system to the toilet . The device will work smoothly for a long time and with the proviso that it is not exposed to water, the temperature of which exceeds 40 degrees.

Lift Station Installation And Sewage Pump Sales In Florida – Florida Keen Sewage Pump Distributor Review

In systems of this type of shredder is located at the top of the housing. Getting in UPKS contaminated water directly into the shredder basket , with dough in it lingers , and the liquid flows into the enclosure. A certain amount of liquid sewage provokes the beginning of diaphragm  engine that drives the chopper blades and fecal pump . Sewage pump evacuates the contents of the device and promoting it through pipes into a septic tank or sewage system. To prevent return of wastewater into the apparatus housing , the flow conduit pipe is equipped with a check valve .

There UPKS this group that can be connected simultaneously to the toilet and sewer to any device, such as the shower or sink.

In installations of this type there is one drawback – the top position of the chopper . Installed in such a position shredder can process not all that it misses and accidentally turned inside item can incapacitate UPKS .

Forced canalization system without chopper cold drains

Compact device that can be connected simultaneously to the sink and shower. UPKS this type can divert waste water up to 100 meters across and 5 meters vertically. The temperature of the wastewater entering this unit should not exceed 40 degrees. The cost of the device – about 330 euros .

Choosing UPKS you need , you need to calculate the required capacity and performance of the installation. If the expected load on UPKS small, better to buy one versatile device . If the home you plan a large number of sanitary ware and expected volumes of wastewater are quite serious – it is better to share the load and to pump waste water using different settings.

Leave a Reply