SpectroScan S spectrometer for the analysis of sulfur in petroleum products

SpectroScan S spectrometer for the analysis of sulfur in petroleum products-Design X-ray fluorescence spectrometer SpectroScan S to select a portion of the mass of sulfur in petroleum and petroleum products. Advised spectrometer for use for quality control of petroleum and petroleum products in accordance with GOST R 51947-02 (ASTM D 4294-98) in terms of “sulfur content” for Standardization TC 31. Passed the Technical Committee spectrometer SpectroScan S tests between laboratories in the parent organization for the refining industry Meteorological Service – JSC “VNIINP”

Design features:

Lateral unique location of the cell with the sample in the sample compartment eliminates spilling food on the tube.
No additional protective film – are excluded from the error of pollution.
Sample compartment is easy to clean.
Eliminating the need for additional protection from the Strait of samples.
Located closer to the sample tube and the detector.
Embedded computer, the keyboard and the screen and the printer.

Advantages:

Spectrometer SpectroScan S is easy to use, required commissioning.
Eliminate the errors caused by the presence of water in mineral oil.
Exclude the possibility of obtaining oil analyst due to cell breakthrough film.
A significant decrease in the analytical signal loss, and as a result, increased sensitivity.
The information is displayed on the sample and the measurement data and printed on a printer included. Printed at one time data on repeatability of measurements in accordance with GOST R ISO 5725-2002. Analyst can be controlled from an external computer.

Spectrometer SpectroScan S greatly simplifies the routine analysis of petroleum and petroleum products on the sulfur content.
Is the reduction of operator actions:
– Are entered with the keyboard built-in number in the sample analyst.
– Sample is placed in two cells, closed 3 micron film.
– Samples were obtained and placed in parallel constantly analyst and start measuring.

SpectroScan S spectrometer for the analysis of sulfur in petroleum products

All subsequent steps spectrometer operates automatically without operator:
– Is calculated and displayed in the sulfur content of the sample S.
– Calculated by determining the difference in the first and second tests in accordance with GOST R ISO 5725-2002.
– At the same time are compared with the reduction of redundancy in accordance with GOST R 51947-2002, ASTM D 4294-98.
– Built-in printer to print the data on the sample (date and the name of the operator, and the number of the sample), and the value and the value of the mass fraction of sulfur in the sample S (average of two replicates)