Why paint the device does not create pressure

Why paint the device does not create pressure?-The main problems encountered in the operation of painting equipment, equipped with a diaphragm pump. Very often, many owners airless painting equipment type face a number of difficulties in its operation. The main problem – the device does not produce feed dye composition, ie Pump does not provide paging.

Why is this happening?

To date, there are four main causes of this fault in new equipment for painting.

The first reason. Too little oil level in the system, or its absence. Typically, this happens when the equipment is sent to the buyer by means of express delivery by air. Terms such transportation is demanded drain all fluids and oil from the unit. It is clear that without oil in the diaphragm pump is not operational, so in this case the oil to pour into the system yourself.

prepare old walls for painting

You can use the oil as recommended by the manufacturer, or any other oil, applicable for this equipment, provided that it is of the highest quality. In this case, it is obligatory to follow the level of the fill, which should be 85-90% of the allowable limit.

The second reason. Adhesiveness of the spring in the valve inlet. This phenomenon may occur in the case of long-term storage device without exploitation. In order to check whether the spring is buildable, you need to click on the valve stem. If the pump is running you will feel the vibrations of the spring, in which case it is efficient.

The third common reason – lack of tightness of the suction system, it leaks. In order to ensure the integrity of the suction system, it is necessary to tighten tight connection pipe and the O-ring inside the nut must be free of damage. If the connections are tight or loose, in a seal is damaged, the system will be able to get the air that does not allow the pump to create enough pressure to perform and download paint formulations.

The fourth reason is inoperable pump – the presence of air in the oil line channels. In the case where the performance of all previous councils did not have any impact on the need to clean the air of all the channels of an oil line. Air can enter these channels as a result of prolonged storage, which will interfere with the working piston, acting on the oil, whereby the membrane will not create oscillatory motion and, as a consequence, the ink composition is not injected. To expel air from the oil line channels, you need to put the bypass valve to the “Circulation” and toggle to put pressure control at minimum. After that, the unit must be enabled for 30 seconds. Pump operation after this procedure will be restored.
Following all these simple guidelines, you can use spray equipment fitted with a diaphragm pump for a long time without a diagnosis and repair.

Leave a Reply